Gill, Jatinder and Singh, Jagdev and Ohunakin, O.S. and Adelekan, Damola (2018) Energetic and exergetic analysis of a domestic refrigerator system with LPG as a replacement for R134a refrigerant, using POE lubricant and mineral oil based TiO 2 -, SiO 2 - and Al 2 O 3 -lubricants. International Journal of Refrigeration, 91. pp. 122-135.
PDF
Download (4MB) |
Abstract
This paper experimentally investigated energetic and exergetic performance analysis of a domestic refrig- erator using R134a and LPG refrigerants with different lubricants (polyol-ester (POE), mineral oil (MO), and TiO 2 , SiO 2 , Al 2 O 3 nanoparticles dispersed in mineral oil).The energetic and exergetic performance analysis of the domestic refrigerator were investigated with test parameters including compressor power consumption, cooling capacity, coefficient of performance (COP), discharge temperature, irreversibility in the components, total irreversibility and second law efficiency. Findings showed that the lowest com- pressor power consumption and total irreversibility were observed in refrigerator with 40 g charge of LPG/TiO 2 -MO lubricant (0.2 g/L of TiO 2 ); these values of compressor power consumption and total ir- reversibility were 15.87% and 31.69%, respectively, lower than for R134a/POE lubricant. In addition, the domestic refrigerator using LPG refrigerant at 40 g charge with TiO 2 -MO (0.2 g/L TiO 2 ) lubricant, had the highest COP and second law efficiency among the selected nano-lubricants. These values of COP and second law efficiency were 56.32% and 47.06%, respectively, higher than that of R134a/POE. Futhermore, compressor discharge temperature of the domestic refrigerator with 40 g charge of LPG/TiO 2 -MO lubricant (0.2 g/L of TiO 2 ) was found to be lower than that of R134a/POE. Hence, extended compressor life may be expected with the adoption of TiO 2 -Mineral oil lubricant. It can be concluded that based on energetic and exergetic performance analysis, the domestic refrigerator using the 40 g charge of LPG/TiO 2 -MO (0.2 g/L TiO 2 ) performed better than R134a/POE.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | LPG Nanoparticles COP Total irreversibility Second law efficiency Domestic refrigerator |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Divisions: | Faculty of Engineering, Science and Mathematics > School of Engineering Sciences |
Depositing User: | Mrs Patricia Nwokealisi |
Date Deposited: | 14 Apr 2021 11:28 |
Last Modified: | 14 Apr 2021 11:28 |
URI: | http://eprints.covenantuniversity.edu.ng/id/eprint/13981 |
Actions (login required)
View Item |